Part Number Hot Search : 
MMBR931 105K2 LS244AS CXA2566M SC4626 00393 PW1250 TCR2EF30
Product Description
Full Text Search
 

To Download MPS-45-75 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TOTAL POWER INT'L
45W Single Output Medical Type
Features :
Low leakage current 0.3mA
MPS-45
series
Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 45KHz 3 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT
OUTPUT POWER (max.) VOLTAGE ADJ. RANGE
MPS-45-3.3 3.3V 8A 0 ~ 10.7A 26.4W
MPS-45-5 5V 8A 0 ~ 10.5A 40W 100mVp-p
MPS-45-7.5 7.5V 5.4A 0 ~ 7A 40.5W 100mVp-p
MPS-45-12 12V 3.7A 0 ~ 4.4A 44.4W 100mVp-p
MPS-45-13.5 MPS-45-15 13.5V 3.3A 0 ~ 3.9A 44.6W 100mVp-p 15V 3A 0 ~ 3.5A 45W 100mVp-p
MPS-45-24 24V 1.9A 0 ~ 2.2A 45.6W 100mVp-p
MPS-45-27 27V 1.7A 0 ~ 1.95A 45.9W 100mVp-p
MPS-45-48 48V 1A 0 ~ 1.1A 48W 100mVp-p
52W(+3.3V:35W)with 18CFM min. Forced air convection
6.75 ~ 8.25V 10.8 ~ 13.2V 12.2 ~ 14.85V 13.5 ~ 16.5V 21.6 ~ 26.4V 24.3 ~ 29.7V 43.2 ~ 52.8V 3.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0%
RIPPLE & NOISE (max.) Note.2 80mVp-p
2.97 ~ 3.63V 4.5 ~ 5.5V 3.0% VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION 1.0% 1.0% LOAD REGULATION 3.0% 3.0%
1.0%
3.0%
1.0% 2.0%
1.0%
2.0%
1.0% 2.0%
1.0% 2.0%
1.0% 2.0%
1.0% 2.0%
SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER LOAD
PROTECTION
800ms, 30ms, 20ms/230VAC
1200ms, 30ms, 12ms/115VAC at full load
90 ~ 264VAC 47 ~ 440Hz 65% 1.2A/115VAC
127 ~ 370VDC 72% 75% 0.7A/230VAC 40A/230VAC 76% 76% 77% 78% 78% 78%
COLD START 20A/115VAC <0.3mA / 264VAC
53 ~ 75W (3.3V:36 ~ 55W) rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.46V 5.75 ~ 6.75V 8.63 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V 55.2 ~ 64.8V
OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH
0.04%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes UL2601-1, TUV EN60601-1, IEC601-1 Approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:SHORT
I/P-O/P, I/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11) Class B EMC
(Note 4)
HARMONIC CURRENT EMS IMMUNITY MTBF
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN60601-1-2 Medical level, criteria A 366.1Khrs min. MIL-HDBK-217F (25 ) 127*76.2*28mm (L*W*H) 0.18Kg; 72pcs/15.1Kg/1.35CUFT
OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Mounting holes M1 and M2 should be grounded for EMI purposes.
45W Single Output Medical Type
Mechanical Specification
127
MPS-45
115.8
5.6
series
Unit:mm
5.6
FG
M1
M2
CN2
7 6 .2
6 4 .8
FS1
AC FUSE T2A/250V 1 2
1 2 3 4 5 6
CN1
FS2
AC FUSE T2A/250V
SVR1 LED
4-
3.
8
28
AC Input Connector (CN1) : Molex 5277-02 or equivalent
Pin No. 1 2 Assignment AC/N AC/L Mating Housing Molex 5195 or equivalent Terminal Molex 5194 or equivalent
DC Output Connector (CN2) : Molex 5273-06 or equivalent
Pin No. 1,2,3 4,5,6 Assignment +V -V Mating Housing Molex 5195 or equivalent Terminal Molex 5194 or equivalent
Block Diagram
EMI FILTER RECTIFIERS & FILTER
POWER SWITCHING
RECTIFIERS & FILTER
fosc : 45KHz
+V -V
I/P
FG
O.L.P.
PWM CONTROL
DETECTION CIRCUIT
O.V.P.
Output Derating
Static Characteristics
100
100
Others
90
80
80
60
3.3V,5V
70
LOAD (%)
40
LOAD(%)
0 10 20 30 40 50 60
60 50 40
20
-10
(HORIZONTAL)
90
100
110
135
155
230 264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (V) 60Hz


▲Up To Search▲   

 
Price & Availability of MPS-45-75

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .